11 mw szs gas hot water boiler

11 mw szs gas hot water boiler

Types and advantages of water tube boilers produced by CBM:

1. Oil and gas water tube boiler

Anyang City Minshan Nonferrous Metal Co., Ltd. is a collection of urban mining, renewable resources, energy as one of the economic wisdom of cleaning companies, mainly non-ferrous metal extraction and processing work. Company to conserve energy, cleaner production for the purpose of this concept coincides with the fast boiler. Thus, when the company in the purchase of the product boiler, and fast boiler almost hit it off, by the party to provide a fast 6 tons of steam integrally condensing gas steam boiler (WNS6-1.25.Y.Q).

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 steam boiler combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 11 mw szs hot water boiler combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 ℃, 58MW of 998 ℃. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 ℃. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

After the gas 11 mw szs hot water boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.

11 mw szs gas hot water boiler Related Information

10 mw szs gas hot water boiler for rice mills - WHGLA

100tons oil fired hot water boiler in Algeria. 18tons szs gas hot water boiler for rice mills - Zozen found in 1988, Now mainly produce gas & oil fired boiler, Biomass fired boiler, Coal chain grate boiler, CFB power plant With 30 year experience, Zozen is a leading steam and hot water boiler manufacturer in China. 18tons coal fired chain grate

Get a Quote

1-10 tons steam boiler, 1.4-7 MW hot water boiler,1

2019-11-28 · Type: 1-10 tons steam boiler, 1.4-7 MW hot water boiler Fuel: natural gas, light oil, heavy oil, straw rice husk and other direct-fired fuel, forming biomass, bituminous coal, anthracite, waste gas heat . Applications: textile mills, garment factories, central heating, printing and dyeing factories, hotels, cafeteria, food plants, beverage plants, etc.

Get a Quote

Boiler Product Catalog - |

2015-9-4 · steam boiler is suitable for industrial and living steam consumption; the correspondent capacity hot water boiler is applied for industrial and civil heating purpose. TP-SZL Series Water Pipe Steam Boiler Item Specification of Package and Shop-assembled Water Tube Coal-fired Boiler TP-SZL4-1.25-All TP-SZL4-1.6-All TP-SZL4-2.45-All

Get a Quote

SZS Series Oil&Gas-fired Steam/Hot Water Boiler

SZS Series Oil&Gas-fired Steam/Hot Water Boiler The SZS boiler system uses German Bosch technology industrial boilers safety control system including PLC

Get a Quote

school hot water boiler - ferienwohnung-haus4.de

SZS series gas-fired (oil-fired) hot water boiler The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways.Around the furnace is membrane water cooling tube wall.

Get a Quote

10 Mw Steam Boiler Chemical Engineering

11tons biomass fired boiler bangladesh for building. 11tons gas steam boiler Bangladesh for Building. 2 mw biomass fired boiler(125 views) 3 pass boilers(114 views boiler circulator pump(111 views) automatic feeding hot water boiler(111 views) the capacity is 2tons szs gas hot water boiler n Chemical Engineering(110 views) Tunisia coffee ground

Get a Quote

SZS Series Gas and Oil Fired Water Tube Packaged Boiler

2016-3-8 · boiler solutions for commercial and industrial applications. D Type Water tube Boiler The SZS is a modern D-type water tube boiler design, with gas tight membrane wall construction for all furnace walls including the front wall to maximise heat transfer. Tube manipulations for burner and man door penetration maintains optimum circulation.

Get a Quote

SZS Gas-fired hot water boiler -

2020-3-9 · SZS Gas-fired hot water boiler. SZS Series Boiler is double drums, longitudinal arranged, "D" type chamber structure. Furnace is on right side and convection tube bundle is on the left.

Get a Quote

school hot water boiler - ferienwohnung-haus4.de

SZS series gas-fired (oil-fired) hot water boiler The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways.Around the furnace is membrane water cooling tube wall.

Get a Quote

14 mw boiler ZOZEN Boiler

14 MW SZS series gas fired hot water boiler for heati >Home>case >14 MW SZS series gas fired hot water boiler for heating. 14 MW SZS series gas fired hot water boiler for heating. Equipment: 6 sets of SZS14-1.25/115/70-Q. [email protected] > Get A Quote >

Get a Quote

school hot water boiler - ferienwohnung-haus4.de

SZS series gas-fired (oil-fired) hot water boiler The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways.Around the furnace is membrane water cooling tube wall.

Get a Quote

hot water heating boiler, steam boiler,SZS gas fired

2019-11-28 · SZS series oil and gas fired boiler is a packaged water tube boiler with double drums and D-type layout. Burning oil and gas, this boiler has lower emission of carbon dioxide, NOx (nitrous oxide), SOx (sulfur dioxide) than coal fuels. As an ideal environmental protection product, it obtains approval from government and factories with high efficiency, low energy consumption and less pollution.

Get a Quote

SZS Oil and Gas Fuel Steam Boiler Product Range Offerings

2014-6-30 · SZS Oil and Gas Fuel Hot Water Boiler Product Range Offerings Nominal water outlet pressure (gauge pressure) MPa 1.0 1.25 1.0 1.25 1.25 1.6 Nominal water outlet temperature / water inlet temperature / °C 95/70 95/70 95/70 115/70 115/70 130/70 150/90 Nominal thermal power MW 7.0 10.5

Get a Quote

SZS Series Gas and Oil Fired Water Tube Packaged Boiler

2016-3-8 · boiler solutions for commercial and industrial applications. D Type Water tube Boiler The SZS is a modern D-type water tube boiler design, with gas tight membrane wall construction for all furnace walls including the front wall to maximise heat transfer. Tube manipulations for burner and man door penetration maintains optimum circulation.

Get a Quote

21MW Industrial Double Drum Diesel Gas Fired Hot

China 21MW Industrial Double Drum Diesel Gas Fired Hot Water Heater, Find details about China Hot Water Boiler, Hot Water Heater from 21MW Industrial Double Drum Diesel Gas Fired Hot Water Heater - Wuxi Zozen Boilers Co., Ltd.

Get a Quote

Do You Want To Get An Exclusive Project Plan ?

7 * 24 * 365 endless service, click the button to provide you with professional and fast solutions at any time

Scroll to Top